8400 HighLine | Parameter setting & configuration
Basic drive functions (MCK)
MCKInterface
380 L Firmware 05.00 - DMS 4.2 EN - 02/2010
bPosSetDataValid
BOOL
Status signal "Position conversion completed, data consistent"
This output is permanently TRUE if the "0: dnPosOut_p=dnPosIn_p" mode has
been set for calculating the position in C01296/1
since this is just a copy process
and not a complex conversion.
TRUE Conversion of the target position from [units] into [increments] has
been completed.
The travel profile data are valid and the profile is ready to start.
dnPosSetOut_p
DINT
Output of the target position in [increments]
•Observe the bPosSetDataValid status output!
wFailState
WORD
Result of the plausibility check
Display parameter: C01299
Result is bit coded:
Bit 0 Invalid operating mode selection
•"1" The selected operating mode is not defined/invalid.
Bit 1 Invalid positioning mode selection
•"1" The selected positioning mode is not defined/invalid.
Bit 2 Invalid profile number selection
•"1" The selected profile number refers to a profile data set that
does not exist.
Bit 3 Reserved
...
Bit 15
bFail
BOOL
FALSE Okay, no error
TRUE Plausibility check error or
control information error (in this case after ORing the individual
signals with the control words)
Identifier
Data type
Value/meaning