8400 HighLine | Parameter setting & configuration
Basic drive functions (MCK)
Basic settings
386 L Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010
 
Short overview of machine parameters:
After the machine parameters have been entered, the drive controller sends back
application-relevant data via the following display parameters:
Parameter Info Lenze setting
Value Unit
C00011 Appl.: Reference speed 1500 rpm
C01202/1
iM: Numerator (motor speed Z2xZ4) 1
C01202/2
iM: Denominator (system speed Z1xZ3) 1
C01203/1
iG: Numerator (motor speed) 1
C01203/2
iG: Denominator (encoder speed) 1
C01204
Axis data: Feed constant 360.0000 units/rev.
C01206/1
Mounting direction: Motor 0: Not inverted
C01206/2
Mounting direction: Position encoder 0: Not inverted
Highlighted in grey = display parameter
Parameter Info Lenze setting
Value Unit
C00057 Maximum torque - Nm
C01205 Axis data: Position resolution
 • Is needed for the incremental specification of 
positions.
- incr/unit
C01210/5 MCK: Positioning accuracy
 • Theoretical accuracy during positioning with 
account being taken of the machine data and 
encoder data.
- units
C01211/1 Max. traversing speed 100%_C11
 • Is used for orientation when the velocity is being 
set in the profile sets.
- units/s
C01213/1 MCK: Max. travel distance - units
Highlighted in grey = display parameter
efesotomasyon.com - Lenze