8400 HighLine | Parameter setting & configuration
Device control (DCTRL)
Controller commands
68 L Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010
 
Controller commands - short overview
Activate controller command
When an online connection has been established, you can simply use the »Engineer« to
activate a controller command by selecting the corresponding option from the Parameters
tab in C00002/x
 ("0: Off" or "1: On / start").
 Alternatively, the controller command can also be activated via e.g. keypad or through 
a master control by writing to C00002/x
.
 Some of the frequently used controller commands (such as "Save parameter set") can 
also be executed via toolbar icons of the »Engineer« when an online connection has 
been established:
C00002
Subcode:
Controller command Controller inhibit 
required
Status information
1 Load Lenze setting
z dynamic
6 Load all parameter sets
z dynamic
11 Save all parameter sets
dynamic
16 Enable/Inhibit controller
static
17 Activate/Deactivate quick stop
static
19 Reset error
static
21 Delete logbook
static
23 Identify motor parameter
z dynamic
26 CAN reset node
static
* Subcodes which are not listed are reserved for future extensions.
Symbol Function
Enable controller
Inhibit controller
Save parameter set (for 8400: Save all parameter sets)
 Note!
Controller commands that can be executed via the toolbar of the »Engineers« 
always affect the element currently selected in the Project view including all 
subelements!
 • If no controller, but e.g. a system module is selected in the Project view, the 
corresponding controller command will be activated in all lower-level 
controllers having an online connection with the »Engineer«.
Before the desired action is carried out, a confirmation prompt appears first, 
asking whether the action is really to be carried out.
efesotomasyon.com - Lenze