Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010 L 695
8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00701
C00701/16 0: Not connected LA_NCtrl: bJogRamp8
(selection input for additional acceleration/deceleration
times)
C00701/17 0: Not connected LA_NCtrl
: bMPOTInAct
(control input for deactivation of motor potentiometer)
C00701/18 0: Not connected LA_NCtrl
: bMPOTUp
(control input for motor potentiometer ramp-up)
C00701/19 0: Not connected LA_NCtrl
: bMPOTDown
(control input for motor potentiometer ramp-down)
C00701/20 0: Not connected LA_NCtrl
: bMBRKRelease
(control input for manual holding brake release request)
C00701/21 0: Not connected LA_NCtrl
: bMANJogPos
(control input for manual jog in positive direction
request)
C00701/22 0: Not connected LA_NCtrl
: bMANJogNeg
(control input for manual jog in negative direction
request)
C00701/23 0: Not connected LA_NCtrl
: bGPAnalogSwitchSet
(control input for analog-value selector change-over)
C00701/24 0: Not connected LA_NCtrl
: bGPDigitalDelayIn
(input for digital signal with time delay)
C00701/25 0: Not connected LA_NCtrl
: bGPLogicIn1
(input signal 1 for digital logic)
C00701/26 0: Not connected LA_NCtrl
: bGPLogicIn2
(input signal 2 for digital logic)
C00701/27 0: Not connected LA_NCtrl
: bGPLogicIn3
(input signal 3 for digital logic)
C00701/28 0: Not connected LA_NCtrl
: bGPDFlipFlopInD
(control input for DFlipFlop setting signal)
C00701/29 0: Not connected LA_NCtrl
: bGPDFlipFlopInClk
(control input for DFlipFlop clock signal)
C00701/30 0: Not connected LA_NCtrl
: bGPDFlipFlopInClr
(control input for DFlipFlop reset signal)
C00701/31 0: Not connected LA_NCtrl
: bMPotEnable
(control input for activation of motor potentiometer)
C00701/32 0: Not connected LA_NCtrl
: bPIDEnableInfluenceRamp
(control input for activation of influence of output
correcting variable of PID controller)
C00701/33 0: Not connected LA_NCtrl
: bPIDIOff
(control input for deactivation of PID controller I
component)
C00701/34 20000: C_True LA_NCtrl
: bRLQCw
(control input for activation of CW direction of rotation
of speed setpoint)
C00701/35 0: Not connected LA_NCtrl
: bRLQCcw
(control input for activation of CCW direction of rotation
of speed setpoint)
C00701/36 0: Not connected LA_NCtrl
: bReserved1
C00701/37 0: Not connected LA_NCtrl
: bReserved2
C00701/38 0: Not connected LA_NCtrl
: bReserved3
C00701/39 0: Not connected LA_NCtrl
: bReserved4
C00701/40 0: Not connected LA_NCtrl
: bReserved5
Parameter | Name:
C00701 | LA_NCtrl: digital connection list
Data type: UNSIGNED_16
Index: 23874
d
= 5D42
h
efesotomasyon.com - Lenze