8400 HighLine | Parameter setting & configuration
Parameter reference
Parameter list | C00827
712 L Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010
Selection list
0False
1True
Subcodes Lenze setting Info
C00827/1 0: FALSE bOut for bIn1=0 / bIn2=0 / bIn3=0 / bIn4=0 / bIn5=0
C00827/2 0: FALSE bOut for bIn1=1 / bIn2=0 / bIn3=0 / bIn4=0 / bIn5=0
C00827/3 0: FALSE bOut for bIn1=0 / bIn2=1 / bIn3=0 / bIn4=0 / bIn5=0
C00827/4 0: FALSE bOut for bIn1=1 / bIn2=1 / bIn3=0 / bIn4=0 / bIn5=0
C00827/5 0: FALSE bOut for bIn1=0 / bIn2=0 / bIn3=1 / bIn4=0 / bIn5=0
C00827/6 0: FALSE bOut for bIn1=1 / bIn2=0 / bIn3=1 / bIn4=0 / bIn5=0
C00827/7 0: FALSE bOut for bIn1=0 / bIn2=1 / bIn3=1 / bIn4=0 / bIn5=0
C00827/8 0: FALSE bOut for bIn1=1 / bIn2=1 / bIn3=1 / bIn4=0 / bIn5=0
C00827/9 0: FALSE bOut for bIn1=0 / bIn2=0 / bIn3=0 / bIn4=1 / bIn5=0
C00827/10 0: FALSE bOut for bIn1=1 / bIn2=0 / bIn3=0 / bIn4=1 / bIn5=0
C00827/11 0: FALSE bOut for bIn1=0 / bIn2=1 / bIn3=0 / bIn4=1 / bIn5=0
C00827/12 0: FALSE bOut for bIn1=1 / bIn2=1 / bIn3=0 / bIn4=1 / bIn5=0
C00827/13 0: FALSE bOut for bIn1=0 / bIn2=0 / bIn3=1 / bIn4=1 / bIn5=0
C00827/14 0: FALSE bOut for bIn1=1 / bIn2=0 / bIn3=1 / bIn4=1 / bIn5=0
C00827/15 0: FALSE bOut for bIn1=0 / bIn2=1 / bIn3=1 / bIn4=1 / bIn5=0
C00827/16 0: FALSE bOut for bIn1=1 / bIn2=1 / bIn3=1 / bIn4=1 / bIn5=0
C00827/17 0: FALSE bOut for bIn1=0 / bIn2=0 / bIn3=0 / bIn4=0 / bIn5=1
C00827/18 0: FALSE bOut for bIn1=1 / bIn2=0 / bIn3=0 / bIn4=0 / bIn5=1
C00827/19 0: FALSE bOut for bIn1=0 / bIn2=1 / bIn3=0 / bIn4=0 / bIn5=1
C00827/20 0: FALSE bOut for bIn1=1 / bIn2=1 / bIn3=0 / bIn4=0 / bIn5=1
C00827/21 0: FALSE bOut for bIn1=0 / bIn2=0 / bIn3=1 / bIn4=0 / bIn5=1
C00827/22 0: FALSE bOut for bIn1=1 / bIn2=0 / bIn3=1 / bIn4=0 / bIn5=1
C00827/23 0: FALSE bOut for bIn1=0 / bIn2=1 / bIn3=1 / bIn4=0 / bIn5=1
C00827/24 0: FALSE bOut for bIn1=1 / bIn2=1 / bIn3=1 / bIn4=0 / bIn5=1
C00827/25 0: FALSE bOut for bIn1=0 / bIn2=0 / bIn3=0 / bIn4=1 / bIn5=1
C00827/26 0: FALSE bOut for bIn1=1 / bIn2=0 / bIn3=0 / bIn4=1 / bIn5=1
C00827/27 0: FALSE bOut for bIn1=0 / bIn2=1 / bIn3=0 / bIn4=1 / bIn5=1
C00827/28 0: FALSE bOut for bIn1=1 / bIn2=1 / bIn3=0 / bIn4=1 / bIn5=1
C00827/29 0: FALSE bOut for bIn1=0 / bIn2=0 / bIn3=1 / bIn4=1 / bIn5=1
C00827/30 0: FALSE bOut for bIn1=1 / bIn2=0 / bIn3=1 / bIn4=1 / bIn5=1
C00827/31 0: FALSE bOut for bIn1=0 / bIn2=1 / bIn3=1 / bIn4=1 / bIn5=1
C00827/32 0: FALSE bOut for bIn1=1 / bIn2=1 / bIn3=1 / bIn4=1 / bIn5=1
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00827 | L_DigitalLogic5_2: Truth table
Data type: UNSIGNED_8
Index: 23748
d
= 5CC4
h