8400 HighLine | Parameter setting & configuration
Parameter reference
Table of attributes
810 L Firmware 05.00 - DMS 4.2 EN - 02/2010
C00028 AINx: Input voltage 24547 5FE3 A 2 INTEGER_16 100 ;
C00029
AINx: Input current 24546 5FE2 A 2 INTEGER_16 100 ;
C00033
AINx: Output value 24542 5FDE A 2 INTEGER_16 100 ;
C00034
AINx: Configuration 24541 5FDD A 2 UNSIGNED_8 1 ;;
C00036
DCB: Current 24539 5FDB E 1 INTEGER_16 100 ;;
C00039
Fixed setpoint x (L_NSet_1 n-Fix) 24536 5FD8 A 15 INTEGER_16 100 ;;
C00050
MCTRL: Speed setpoint 24525 5FCD E 1 INTEGER_32 1 ;
C00051
MCTRL: Actual speed value 24524 5FCC E 1 INTEGER_32 1 ;
C00052
Motor voltage 24523 5FCB E 1 UNSIGNED_16 1 ;
C00053
DC-bus voltage 24522 5FCA E 1 UNSIGNED_16 1 ;
C00054
Motor current 24521 5FC9 E 1 UNSIGNED_16 100 ;
C00056
Torque 24519 5FC7 A 2 INTEGER_32 100 ;
C00057
Maximum torque 24518 5FC6 E 1 UNSIGNED_32 100 ;
C00058
Output frequency 24517 5FC5 E 1 INTEGER_32 100 ;
C00059
Appl.: Reference frequency C11 24516 5FC4 E 1 UNSIGNED_32 100 ;
C00061
Heatsink temperature 24514 5FC2 E 1 INTEGER_16 1 ;
C00064
Device utilisation (Ixt) 24511 5FBF A 3 INTEGER_16 100 ;
C00065
Supply voltage 24V 24510 5FBE E 1 INTEGER_16 10 ;
C00066
Thermal motor load (I²xt) 24509 5FBD E 1 INTEGER_16 100 ;
C00070
Vp speed controller 24505 5FB9 A 2 UNSIGNED_16 100 ;;
C00071
Ti speed controller 24504 5FB8 A 2 UNSIGNED_16 10 ;;
C00072
SC: Tdn speed controller 24503 5FB7 E 1 UNSIGNED_16 100 ;;
C00073
Imax/M controller gain 24502 5FB6 A 2 UNSIGNED_16 100 ;;
C00074
Imax/M controller reset time 24501 5FB5 A 2 UNSIGNED_16 1 ;;
C00075
Vp current controller 24500 5FB4 E 1 UNSIGNED_16 100 ;;
C00076
Ti current controller 24499 5FB3 E 1 UNSIGNED_16 100 ;;
C00077
SC: Vp field controller 24498 5FB2 E 1 UNSIGNED_16 100 ;;
C00078
SC: Tn field controller 24497 5FB1 E 1 UNSIGNED_16 10 ;;
C00079
SC: Settings 24496 5FB0 A 3 UNSIGNED_8 1 ;;
C00080
Override point of field weakening 24495 5FAF E 1 INTEGER_16 1 ;;
C00081
Rated motor power 24494 5FAE E 1 UNSIGNED_16 100 ;;
C00082
Motor rotor resistance 24493 5FAD E 1 UNSIGNED_32 1 ;;
C00083
Motor rotor time constant 24492 5FAC E 1 UNSIGNED_16 1 ;
C00084
Motor stator resistance 24491 5FAB E 1 UNSIGNED_32 1 ;;
C00085
Motor stator leakage inductance 24490 5FAA E 1 UNSIGNED_16 100 ;;
C00087
Rated motor speed 24488 5FA8 E 1 UNSIGNED_16 1 ;;
C00088
Rated motor current 24487 5FA7 E 1 UNSIGNED_16 100 ;;
C00089
Rated motor frequency 24486 5FA6 E 1 UNSIGNED_16 1 ;;
C00090
Rated motor voltage 24485 5FA5 E 1 UNSIGNED_16 1 ;;
C00091
Motor cosine phi 24484 5FA4 E 1 UNSIGNED_8 100 ;;
C00092
Motor magnetising inductance 24483 5FA3 E 1 UNSIGNED_16 10 ;;
C00093
Power section ID 24482 5FA2 E 1 UNSIGNED_16 1 ;
C00095
Motor magnetising current 24480 5FA0 E 1 UNSIGNED_16 100 ;;
C00097
Rated motor torque 24478 5F9E E 1 UNSIGNED_32 100 ;
C00098
Rated device current 24477 5F9D E 1 UNSIGNED_16 10 ;
C00099
Firmware version 24476 5F9C E 1 VISIBLE_STRING ;
C00100
Firmware version 24475 5F9B A 4 UNSIGNED_8 1 ;
C00101
Add. acceleration time x 24474 5F9A A 15 UNSIGNED_32 1000 ;;
C00103
Add. deceleration time x 24472 5F98 A 15 UNSIGNED_32 1000 ;;
C00105
Deceleration time - quick stop 24470 5F96 E 1 UNSIGNED_32 1000 ;;
C00106
Auto-DCB: Hold time 24469 5F95 E 1 UNSIGNED_32 1000 ;;