8400 HighLine | Parameter setting & configuration
Working with the FB Editor
Reconfiguring the predefined interconnection
860 L Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010
 
 How to change the processing order manually:
1. Use the list field at the top right to change from the Editor to the overview.
 • The overview displays all function blocks of the interconnection in the order of 
their processing
 • In the first "Order" column the order index of each function block is listed.
2. Unless already selected, select the entry "Manual selection" in the Optimisation... 
list field.
3. Select the function block which is to receive a different position within the 
processing order.
 • If you click further function blocks while pressing <Ctrl> they are added to an 
already existing selection (multi-selection).
 •The <Shift> key serves to select a related area of function blocks.
4. Move the function block(s) to the desired position using the   and   buttons.
 • The   button serves to exchange two selected function blocks with regard to 
their order.
5. Repeat steps 3 and 4 until the required processing order has been established.
efesotomasyon.com - Lenze