8400 HighLine | Parameter setting & configuration
Function library
Function blocks | L_ConvW_1
924 L Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010
 
Conversion formulae
[14-18] Conversion formula for selection 1: [%]  [incr/ms]
[14-19] Conversion formula for selection 2: [incr/ms]  [%]
[14-20] Conversion formula for selection 3: Parameterisable factors
wOut [incr/ms]
wIn [%] C00011 [rpm] 65536 [incr/rev.]⋅⋅
100 % 60 [s/min] 1000 [ms/s]⋅⋅
------------------------------------------------------------------------------------------------------------=
wOut [%]
wIn [incr/ms] 100 % 60 [s/min] 1000 [ms/s]⋅⋅⋅
C00011 [rpm] 65536 [incr/rev.]⋅
---------------------------------------------------------------------------------------------------------------------------=
wOut wIn
C00940
C00941
------------------- -
⋅=