Function
1. A FALSE-TRUE edge at bIn starts the internal timing element for the ON delay.
2. After the defined ON delay, the input signal bIn is output at bOut.
3. A TRUE-FALSE edge at bIn starts the internal timing element for the OFF delay.
4. After the defined OFF delay, the input signal bIn is output at bOut.
n ON delay
o OFF delay
Internal timing element for ON delay (retriggerable)
Internal timing element for OFF delay (retriggerable)
TRUE
FALSE
bOut
t
TRUE
FALSE
bIn
t
t
0
t
1