Firmware 05.00 - DMS 4.2 EN - 02/2010 L 991
8400 HighLine | Parameter setting & configuration
Function library
Function blocks | L_NLim_1
Parameter
Definition of the blocking zones
Up to three zones can be parameterised which are to be skipped by the nOut_a output
signal.
The example below shows the parameter setting of two blocking zones for the L_NLim_1
FB:
[14-29] Zone masking by means of parameterisable blocking zones (in our example: L_NLim_1)
Parameter Possible settings Info
C00807/1...3
0.00 % 199.99 Maximum blocking frequency 1 ... 3
Lenze setting: 0.00 %
C00808/1...3
0.00 % 199.99 Minimum blocking frequency 1 ... 3
Lenze setting: 0.00 %
Parameter Blocking zone 1 Blocking zone 2 Blocking zone 3
Minimum limit value C00808/1: 48 % C00808/2: 138 % C00808/3: 0 %
Maximum limit value C00807/1: 104 % C00807/2: 178 % C00807/3: 0 %
Blocking zone 1
Blocking zone 2
nOut_a [%]
nIn_a
[%]
1
0
199.99
-199.99
-199.99 199.99
C00807/1
C00808/1
48 138
0
1
104 178
C00807/2
C00808/2