EasyManuals Logo

QUANTA LB4M User Manual

QUANTA LB4M
970 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #515 background imageLoading...
Page #515 background image
UANTA COMPUTER INC.
Layer 2,3,IPv6+QoS Switch
_____________________________________________________________________________
Layer 2,3,IPv6+QoS Network Switch User Manual Version 0.1 Page: 515/970
Group-Specific Queries sent in response to Leave Group messages on the interface to
the default value.
Default Setting
1 second
Command Mode
Interface Config
8.2.2.5 ip igmp query-interval
This command configures the query interval for the specified interface. This is the frequency at
which IGMP Host-Query packets are transmitted on this interface.
Syntax
ip igmp query-interval <1-3600>
no ip igmp query-interval
<1-3600> - The range for <1-3600> is 1 to 3600 seconds.
no - This command resets the query interval for the specified interface to the default
value. This is the frequency at which IGMP Host-Query packets are transmitted on this
interface.
.
Default Setting
125 seconds
Command Mode
Interface Config
8.2.2.6 ip igmp query-max-response-time
This command configures the maximum response time interval for the specified interface,
which is the maximum query response time advertised in IGMPv2 queries on this interface.The
time interval is specified in tenths of a second.
Syntax
ip igmp query-max-response-time <0-255>
no ip igmp query-max-response-time
<0-255> - The range for <0-255> is 0 to 255 tenths of a second.