8400 HighLine | Parameter setting & configuration
Basic drive functions (MCK)
Homing
400 L Firmware ≤ 05.00 - DMS 4.2 EN - 02/2010
 
Mode 8: >_TP
Functional sequence:
1. Movement in positive direction with profile data set 1.
2. Following positive edge of the touch probe sensor sets home position.
Mode 9: <_TP
Functional sequence:
1. Movement in negative direction with profile data set 1.
2. Following positive edge of the touch probe sensor sets home position.
Mode 10: >_Lp_<_TP
Functional sequence:
1. Movement in positive direction with profile data set 1.
2. Reversing when the edge of the positive travel range limit switch is positive and, at the 
same time, activation of profile data set 2 for continued reference searching.
3. Following positive edge of the touch probe sensor sets home position.
 Touch probe
 Touch probe
 Touch probe
 Positive travel range limit switch
1
0
1
0
1
0
1
efesotomasyon.com - Lenze