Firmware 05.00 - DMS 4.2 EN - 02/2010 L 545
8400 HighLine | Parameter setting & configuration
System bus "CAN on board"
Monitoring
The maximum number of the nodes to be monitored depends on the device version:
"BaseLine C": 1 Heartbeat Producer can be monitored.
"StateLine": Up to 7 Heartbeat Producers can be monitored.
"HighLine": Up to 15 Heartbeat Producers can be monitored.
The node address(es) of the nodes to be monitored is/are set in C00385/1...n
or via
object I-1016
, too.
Heartbeat event
The "Heartbeat event" is activated in the consumer if it does not receive any heartbeat
telegram from the producer within the heartbeat consumer time:
The consumer changes from the "Operational" communication status to the "Pre-
Operational" communication status.
The NMT master receives an emergency telegram containing emergengy error code
0x8130.
The response parameterised in C00592/5
is activated (Lenze setting: "No response").
Note!
The heartbeat monitoring will not start until the first heartbeat telegram of a
monitored producer has been received successfully and the "Pre-Operational"
NMT status has been assumed.
The boot-up telegram counts as the first heartbeat telegram.