Function blocks | L_Curve_1
 
Exceptions
 Step changes/discontinuities can be displayed by using the same parameter setting for 
two consecutive X values. A step change is only valid if it has a valid pair of variates. 
Otherwise, extrapolation continues, starting at the last valid pair of variates.
[14-23] Example: Characteristic with step change
 If only one interpolation point, x1, in the negative range is defined, x2 exists with the 
"0 %" Lenze setting being the valid interpolation point (x2 > x1), and a line is drawn 
through both interpolation points:
[14-24] Example: Characteristic with only one defined interpolation point and x1 < 0
1 2 3 4 5 6 7 ... 32
X
-130 % -70 % -70 % 80 % 0 % 0 % 0 % 0 % 0 %
y(x)
-150 % -75 % 85 % 160 % 0 % 0 % 0 % 0 % 0 %
nOut_a
nIn_a
x1, y1
x3, y3
x4, y4
-199.99 % / -199.99 %
199.99 % / 199.99 %
x2, y2
1 2 3 4 5 6 7 8 9
X
-130 % 0 %0 %0 %0 %0 %0 %0 %0 %
y(x)
40 % 0 %0 %0 %0 %0 %0 %0 %0 %
nOut_a
nIn_a
x1, y1 x2, y2
-199.99 % / -199.99 %
199.99 % / 199.99 %