UANTA COMPUTER INC.
Layer 2,3,IPv6+QoS Switch
_____________________________________________________________________________
Layer 2,3,IPv6+QoS Network Switch User Manual Version 0.1 Page: 639/970
you select MD5 or SHA, the user login password will be used as the SNMPv3
authentication password, and you must therefore specify a password, and it must be eight
characters.
Encryption Protocol - Specify the SNMPv3 Encryption Protocol setting for the selected
user account. The valid Encryption Protocols are None or DES. If you select the DES
Protocol you must enter a key in the Encryption Key field. If None is specified for the
Protocol, the Encryption Key is ignored.
Encryption Key - If you selected DES in the Encryption Protocol field enter the SNMPv3
Encryption Key here. Otherwise this field is ignored. Valid keys are 8 to 64 characters. The
Apply checkbox must be checked in order to change the Encryption Protocol and
Encryption Key.
Non-Configurable Data
Access Mode - Indicates the user's access mode. The admin account always has
'Read/Write' access, and all other accounts have 'Read Only' access.
SNMP v3 Access Mode - Indicates the SNMPv3 access privileges for the user account.
The admin account always has 'Read/Write' access, and all other accounts have 'Read
Only' access.
Lockout Status - Indicates whether the user account is locked due to excessive failed
login attempts. The threshold for number of attempts before lockout is specified by 'lockout
attempts' on the password management page.
Password Expiration Date - Displays the date after which the user will be required to
change passwords if password aging is enabled.
Command Buttons
Submit - Update the switch with the values on this screen. If you want the switch to retain
the new values across a power cycle, you must perform a save.
Delete - Delete the currently selected user account. If you want the switch to retain the
new values across a power cycle, you must perform a save. This button is only visible
when you have selected a user account with 'Read Only' access. You cannot delete the
'Read/Write' user.