UANTA COMPUTER INC.
Layer 2,3,IPv6+QoS Switch
_____________________________________________________________________________
Layer 2,3,IPv6+QoS Network Switch User Manual Version 0.1 Page: 938/970
Reachable Routes - The number of routes in the DVMRP routing table that have a
non-infinite metric.
Command Buttons
Submit - Send the updated configuration to the switch. Configuration changes take effect
immediately. These changes will not be retained across a power cycle unless a save is
performed.
11.2.7.1.2. Configuring DVMRP Interface Configuration Page
Selection Criteria
Slot/Port - Select the interface for which data is to be configured. You must configure at
least one router interface before you configure a DVMRP interface. Otherwise you will see
a message telling you that no router interfaces are available, and the configuration screen
will not be displayed.
Configurable Data
Interface Mode - Select enable or disable from the pull-down menu to set the
administrative mode of the selected DVMRP routing interface.
Interface Metric - Enter the DVMRP metric for the selected interface. This value is sent in
DVMRP messages as the cost to reach this network. Valid values are from (1 to 31).
Command Buttons
Submit - Send the updated configuration to the switch. Configuration changes take effect
immediately. These changes will not be retained across a power cycle unless a save is
performed.