Layer 2,3,IPv6+QoS Switch
_____________________________________________________________________________
Layer 2,3,IPv6+QoS Network Switch User Manual Version 0.1 Page: 693/970
11.2.1.11.4. Viewing SNTP Server Status Page
Non-Configurable Data
Address - Specifies all the existing Server Addresses. If no Server configuration exists, a
message saying "No SNTP server exists" flashes on the screen.
Last Update Time - Specifies the local date and time (UTC) that the response from this
server was used to update the system clock.
Last Attempt Time - Specifies the local date and time (UTC) that this SNTP server was
last queried.
Last Attempt Status - Specifies the status of the last SNTP request to this server. If no
packet has been received from this server, a status of Other is displayed.
•
Other None of the following enumeration values.
•
Success The SNTP operation was successful and the system time was
updated.
•
Request Timed Out A directed SNTP request timed out without receiving a
response from the SNTP server.
•
Bad Date Encoded The time provided by the SNTP server is not valid.
•
Version Not Supported The SNTP version supported by the server is not
compatible with the version supported by the client.
•
Server Unsychronized The SNTP server is not synchronized with its peers.
This is indicated via the 'leap indicator' field on the SNTP message.
•
Server Kiss Of Death The SNTP server indicated that no further queries were
to be sent to this server. This is indicated by a stratum field equal to 0 in a message
received from a server.
Unicast Server Num Requests - Specifies the number of SNTP requests made to this
server since last time agent reboot.
Unicast Server Num Failed Requests - Specifies the number of failed SNTP requests
made to this server since last reboot.