Enhanced Queued Analog-to-Digital Converter (eQADC)
MPC5566 Microcontroller Reference Manual, Rev. 2
19-32 Freescale Semiconductor
Table 19-19. EQADC_SSICR Field Descriptions
Field Description
0–20 Reserved.
21–23
MDT
[0:2]
Minimum delay after transmission. Defines the minimum delay after transmission time (t
MDT
) expressed in serial
clock (FCK) periods. t
MDT
is the minimum time SDS should be kept negated between two consecutive serial
transmissions. Table 19-20 lists the minimum delay after transfer time according to how MDT is set.
The MDT field must only be written when the serial transmissions from the eQADC SSI are disabled - Refer to
EQADC_MCR[ESSIE] field in Section 19.3.2.1, “eQADC Module Configuration Register (EQADC_MCR)”.
24–27 Reserved.
28–31
BR
[0:3]
Baud rate. Selects system clock divide factor as shown in Table 19-21. The baud clock is calculated by dividing the
system clock by the clock divide factor specified with the BR field.
Note: The BR field must only be written when the eQADC SSI is disabled - Refer to EQADC_MCR[ESSIE] field in
Section 19.3.2.1, “eQADC Module Configuration Register (EQADC_MCR).”
Table 19-20. Minimum Delay After Transmission (t
MDT
) Time
MDT
t
MDT
(FCK period)
0b000 1
0b001 2
0b010 3
0b011 4
0b100 5
0b101 6
0b110 7
0b111 8
Table 19-21. System Clock Divide Factor for Baud Clock
BR[0:3] System Clock Divide Factor
1
0b0000 2
0b0001 3
0b0010 4
0b0011 5
0b0100 6
0b0101 7
0b0110 8
0b0111 9
0b1000 10
0b1001 11