RUGGEDCOM ROX II
User Guide
Chapter 5
Setup and Configuration
Configuring a Basic IPv6 Network 239
Section 5.1.2
Configuring a Basic IPv6 Network
To configure a basic IPv6 network, do the following:
1. Connect a computer to the Fast Ethernet port (fe-cm-1) of the device and configure the computer to be on
the same subnet as the port.
2. Configure an IPv6 address and default gateway for the computer (e.g. FDD1:9AEF:3DE4::1/24 and
FDD1:9AEF:3DE4::2).
3. Configure the fe-cm-1 and switch.0001 interfaces on the device with IPv6 addresses.
4. Connect one of the switched ports from any available line module to an IPv6 capable network.
5. Configure the computers on the IPv6 network to be on the same IP subnet as switch.0001 and configure the
default gateway address.
6. Enable IPv6 Neighbor Discovery. For more information, refer to Section 5.38.4, “Configuring IPv6 Neighbor
Discovery”.
7. Verify the computers connected to switch.001 can be seen by the computer connected to fe-cm-1.
Section 5.2
Configuring ICMP Control
To configure how ROX II manages ICMP redirect messages, do the following:
1. Change the mode to Edit Private or Edit Exclusive.
2. Navigate to admin. The System Control form appears.