RUGGEDCOM ROX II
User Guide
Chapter 5
Setup and Configuration
Viewing a List of Link Failover Ping Targets 609
Section 5.27.5.1
Viewing a List of Link Failover Ping Targets
To view a list of link failover ping targets, navigate to services » link-failover » {interface} » target, where
{interface} is the name of the interface. If ping targets have been configured, the Targets IP Addresses table
appears.
Figure 711: Targets IP Addresses Table
If no ping targets have been configured, add targets as needed. For more information, refer to Section 5.27.5.2,
“Adding a Link Failover Ping Target”.
Section 5.27.5.2
Adding a Link Failover Ping Target
To add a link failover ping target, do the following:
NOTE
Link failover pings each target separately. If all targets are down, the main link is considered to be
down and it fails over to the backup interface. Backup links are used in the order of their Priority setting
(first, second, and then third), always starting with the first priority interface. When a higher-priority
interface becomes available again, the system reverts to the higher priority interface. For example, if
the second priority interface is active, the system switches back to the first priority interface when the
first priority interface becomes available again.
1. Change the mode to Edit Private or Edit Exclusive.
2. Navigate to services » link-failover » {interface} » target, where {interface} is the name of the interface.
3. Click <Add target>. The Key Settings form appears.
1
2
Figure 712: Key Settings Form
1. Host IP Box 2. Add Button