EasyManua.ls Logo

Siemens RX1500

Siemens RX1500
856 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 5
Setup and Configuration
RUGGEDCOM ROX II
User Guide
426 Adding an LSP Lifetime Interval
Figure 467: Maximum LSP Lifetime Routing Type
If no intervals have been configured, add intervals as needed. For more information, refer to Section 5.18.8.2,
“Adding an LSP Lifetime Interval”.
Section 5.18.8.2
Adding an LSP Lifetime Interval
To add an LSP lifetime interval to an IS-IS area, do the following:
IMPORTANT!
The LSP lifetime interval must be 300 seconds higher than the LSP refresh interval. For more
information about LSP refresh intervals, refer to Section 5.18.9, “Managing LSP Refresh Intervals”.
1. Navigate to routing » dynamic » isis » area » {name} » max-lsp-lifetime, where {name} is the unique
name for a routing process that belongs to a specific router.
2. Click <Add is-type>. The Key Settings form appears.
2
1
Figure 468: Key Settings Form
1. Routing Type List 2. Add Button
3. Configure the following parameter(s) as required:
Parameter Description
Routing Type Synopsis: level-1-only, level-2-only, level-1-2
The IS type for this setting, specified as level-1-only, level-2-only or level-1-2.
4. Click Add to create the new limit. The Maximum LSP Lifetime Routing Type form appears.

Table of Contents

Related product manuals