User Permissions 9
Services Port Number Port Open
Port
Default
Access
Authorized
RADIUS UDP/1812 to send, opens random port
to listen
Open (if configured) Closed Yes
L2TP Random Port Open (if configured) Closed Yes
Section 1.5
User Permissions
The following table lists the operation, configuration, and action commands permitted to the administrator,
operator, and guest users.
Types of user access:
Create (C) - can create and remove optional parameters
Execute (E) - can run an action or command
No - no read/write/execute access
Read (R) - read access
Update (U) - can modify existing parameter
Access
Commands/Paths Permitted
Administrator Operator Guest
Notes
config private | exclusive | no-confirm Allowed Allowed No
/admin/software-upgrade R/U No No
/admin/rox-imaging R/U No No
/admin/authentication R/U No No
/admin/authentication/password-complexity R/U R No
/admin/logging C/R/U No No
/admin/alarms (status) R R No Administrator and operator can see status
of active-alarms, acknowledge and clear
alarms
/admin/alarms-config/ R/U R/U No Administrator and operator cannot create or
delete alarm-lists
/admin/users C/R/U No No
/admin/users/userid R/U R/U No Operator can only change own password
and cannot create users.
/admin/cli R/U R/U No
/admin/snmp C/R/U No No
/admin/netconf R/U No No
/admin/dns C/R/U No No
/admin/webui R/U R/U No
/admin/scheduler C/R/U No No

Table of Contents