Chapter 3
Device Management
RUGGEDCOM ROX II
User Guide
118 Restarting the Serial Server
Parameter Description
The number of data bits.
parity Synopsis: none, even, odd
Default: none
The parity of the serial port.
stop-bits Default: 1
The number of stop bits of the serial port.
flow-control Synopsis: none, xonxoff
Default: none
The flow control of the serial port.
port-type Synopsis: rs232, rs422, rs485
Default: rs232
The type of serial port.
4. Click Commit to save the changes or click Revert All to abort. A confirmation dialog box appears. Click OK
to proceed.
5. Click Exit Transaction or continue making changes.
Section 3.20.7
Restarting the Serial Server
To restart the serial server, do the following:
1. Navigate to interfaces » serial and click restart-serserver in the menu. The Trigger Action form appears.
Figure 120: Trigger Action Form
1. Perform Button
2. Click Perform.
Section 3.20.8
Resetting a Serial Port
To reset a serial port, do the following: