Chapter 3
Device Management
RUGGEDCOM ROX II
User Guide
36 Viewing the Slot Sensor Status
Parameter Description
Status The runtime status of the installed module.
Uptime The total time elapsed since the start-up of the installed module.
Boot Date The date on which the installed module was started up.
Boot Time The time at which the installed module was started up.
Section 3.2.6
Viewing the Slot Sensor Status
To view information about the slot sensors, navigate to chassis » sensors. The Slot Sensors table appears..
Figure 24: Slot Sensors Table
This table provides the following information:
Parameter Description
slot Synopsis: pm1, pm2, main, sm, lm1, lm2, lm3, lm4, lm5, lm6, cm, em, trnk
The slot name, as marked on the silkscreen across the top of the chassis.
Detected Module The installed module's type specifier.
Temperature (degrees C) The temperature, in degrees C, of the installed module. If multiple temperature sensors are
present on the board, the maximum reading is reported.
Power Supply (mA) The power supply current, in mA, being drawn by the installed module.
Power Supply (mV) The power supply voltage, in mV, seen by the installed module.
Section 3.2.7
Viewing the Power Controller Status
To view the status of the power controller, navigate to chassis » power-controller. The Power Status table
appears.