Chapter 5
Setup and Configuration
RUGGEDCOM ROX II
User Guide
810 Viewing a List of Static Cross-Connects
Parameter Description
Local Label The incoming (local) label.
Outgoing Label The outgoing (remote) label.
Outgoing Interface The outgoing interface.
Next Hop The destination next hop router.
If no static cross-connects have been configured, add cross-connects as needed. For more information about
adding static cross-connects, refer to Section 5.39.6.3, “Adding a Static Cross-Connect”.
Section 5.39.6.2
Viewing a List of Static Cross-Connects
To view a list of configured static cross-connects, navigate to mpls » static-mpls » crossconnect. If cross-
connect labels have been configured, the Static MPLS Cross-Connects table appears.
Figure 935: Static MPLS Cross-Connects Table
If no static cross-connects have been configured, add cross-connects as needed. For more information about
adding static cross-connects, refer to Section 5.39.6.3, “Adding a Static Cross-Connect”.
Section 5.39.6.3
Adding a Static Cross-Connect
To add a static cross-connect, do the following:
1. Change the mode to Edit Private or Edit Exclusive.
2. Navigate to mpls » static-mpls » crossconnect and click <Add dest-address>. The Key Settings form
appears.