RUGGEDCOM ROX II
User Guide
Chapter 5
Setup and Configuration
Enabling and Configuring SNMP Sessions 257
Standard MIB Trap and Description
The main subtree for the RUGGEDCOM software upgrade trap.
trapCfgChangeTrap
The main subtree for the RUGGEDCOM configuration change trap.
trapFanBankTrap
The main subtree for the RUGGEDCOM fan bank trap.
trapHotswapModuleStateChangeTrap
The main subtree for the RUGGEDCOM fan hot-swap module state change trap.
RFC 3895 DS1-MIB ds1LineStatusChange
A ds1LineStatusChange trap is sent when the status of a dsx1Line instance
changes. The value of the trap is the value of one or more of the following
instances:
dsx1RcvFarEndLOF – Far end Loss of Frames (i.e. yellow alarm or RAI)
dsx1RcvAIS – Far end sending AIS
dsx1LossOfFrame – Near end Loss of Frame (i.e. red alarm)
dsx1LossofSignal – Near end Loss of Signal
dsx1OtherFailure – Out of Frame
dsx1NoAlarm
Section 5.11.2
Enabling and Configuring SNMP Sessions
To enable and configure SNMP sessions, do the following:
1. Change the mode to Edit Private or Edit Exclusive.
2. Navigate to admin » snmp. The SNMP Sessions form appears.