RUGGEDCOM ROX II
User Guide
Chapter 3
Device Management
Managing Diagnostic Logs 45
1
Figure 34: Trigger Action Form
1. Perform Button
2. Click Perform.
Section 3.9.3
Managing Diagnostic Logs
Diagnostic logs are available for troubleshooting the device. Various device behaviour is recorded in the following
logs:
Log Filename
Developer's Log /var/log/confd-dev.log
SNMP Log /var/log/snmp-trace.log
NETCONF Summary Log /var/log/netconf.log
NETCONF Trace Log /var/log/netconf-trace.log
XPATH Trace Log /var/log/xpath-trace.log
WebUI Trace Log /var/log/webui-trace.log
CAUTION!
Configuration hazard – risk of reduced performance. Enabling diagnostic logging will significantly affect
the performance of ROX II. Only enable diagnostic logging when directed by Siemens.
The following sections describe how to configure and manage diagnostic logs:
Section 3.9.3.1, “Enabling/Disabling the Developer's Log”
Section 3.9.3.2, “Enabling/Disabling the SNMP Log”
Section 3.9.3.3, “Enabling/Disabling the NETCONF Summary Log”
Section 3.9.3.4, “Enabling/Disabling the NETCONF Trace Log”
Section 3.9.3.5, “Enabling/Disabling the XPATH Trace Log”
Section 3.9.3.6, “Enabling/Disabling the WebUI Trace Log”