RUGGEDCOM ROX II
User Guide
Chapter 5
Setup and Configuration
Configuring a Routing Interface 533
1
2
3
4
6
5
7
Figure 618: Interface Parameters Form
1. Authentication Type List 2. Link Cost Box 3. Hello Interval Box 4. Priority Box 5. Passive Interface Box 6. Retransmit
Interval Box 7. Transmit Delay Box
3. On the Dead Interval form, configure the following parameter(s) as required:
NOTE
For reliable operation, it is recommended that the Dead Interval value be at least four times the
number of Hellos per second.
NOTE
Lower values of Dead Interval and Number of Hellos Per Second will help speed up the change
in network routes when the topology of the network changes. It will also increase the load on the
router and the links, due to higher traffic caused by the increase in messages.
Lower values will also put limits on the number of routes that can be distributed within an OSPF
network area, as will running over slower links.
IMPORTANT!
The Dead Interval and number of Hellos per second must be identical on every router in an OSPF
network area.