Remote control commands
R&S
®
RTE
1190User Manual 1326.1032.02 ─ 20
For the ranges "Shorter" and "Longer", the width defines the maximum and minimum
pulse width, respectively.
Suffix:
<m>
.
1..3
Only 1 = A-trigger, 2 | 3 = not available. Can be omitted.
Parameters:
<Width> Range: 100E-12 to 10000
Increment: 100E-9
*RST: 5E-9
Default unit: s
Usage: Asynchronous command
TRIGger<m>:PATTern:WIDTh:DELTa
<WidthDelta>
Defines a range around the width value specified using TRIGger<m>:PATTern:
WIDTh[:WIDTh].
Suffix:
<m>
.
1..3
Only 1 = A-trigger, 2 | 3 = not available. Can be omitted.
Parameters:
<WidthDelta> Range: 0 to 432
Increment: 500E-12
*RST: 0
Default unit: s
Usage: Asynchronous command
18.9.13 Serial pattern trigger
The serial pattern trigger is only available for the A-event (Suffix = 1).
TRIGger<m>:SPATtern:CSOurce[:VALue].......................................................................1190
TRIGger<m>:SPATtern:CSOurce:EDGE.........................................................................1191
TRIGger<m>:SPATtern:CSOurce:LEVel..........................................................................1191
TRIGger<m>:SPATtern:PATTern.................................................................................... 1191
TRIGger<m>:SPATtern:REFSource................................................................................1192
TRIGger<m>:SPATtern:CSOurce[:VALue] <ClockSource>
Defines the source of the clock signal.
Suffix:
<m>
.
1..3
Only 1 = A-trigger, 2 | 3 = not available. Can be omitted.
Trigger