Remote control commands
R&S
®
RTE
1676User Manual 1326.1032.02 ─ 20
Parameters:
<SymbolRate> Range: 10 to 150
Increment: 1E-3
*RST: 66.6667
Default unit: MSymb/s
18.17.13.2 Trigger
The trigger suffix <m> is always 1 and can be omitted. It selects the trigger event: Only
the A-trigger is available for triggering on serial buses.
To trigger on a serial bus, make sure that:
●
TRIGger<m>:SOURce[:SELect] is set to SBUS.
●
The sources of the serial bus are channel signals: use BUS<m>:...:SOURce
commands.
●
Decoding is enabled: BUS<m>[:STATe] is set to ON.
TRIGger<m>:HBTO:TYPE............................................................................................ 1676
TRIGger<m>:HBTO:DADDress:CONDition.....................................................................1677
TRIGger<m>:HBTO:DADDress:MIN.............................................................................. 1677
TRIGger<m>:HBTO:DADDress:MAX............................................................................. 1678
TRIGger<m>:HBTO:SADDress:CONDition..................................................................... 1678
TRIGger<m>:HBTO:SADDress:MIN...............................................................................1678
TRIGger<m>:HBTO:SADDress:MAX..............................................................................1679
TRIGger<m>:HBTO:LENGth:CONDition.........................................................................1679
TRIGger<m>:HBTO:LENGth:MIN.................................................................................. 1679
TRIGger<m>:HBTO:LENGth:MAX................................................................................. 1679
TRIGger<m>:HBTO:CRC:CONDition............................................................................. 1680
TRIGger<m>:HBTO:CRC:MIN.......................................................................................1680
TRIGger<m>:HBTO:CRC:MAX......................................................................................1680
TRIGger<m>:HBTO:DATA:DCONdition.......................................................................... 1681
TRIGger<m>:HBTO:DATA:DMIN................................................................................... 1681
TRIGger<m>:HBTO:DATA:DMAX.................................................................................. 1681
TRIGger<m>:HBTO:DATA:ICONdition............................................................................1682
TRIGger<m>:HBTO:DATA:IMIN.....................................................................................1682
TRIGger<m>:HBTO:DATA:IMAX....................................................................................1682
TRIGger<m>:HBTO:ERRor:PREamble...........................................................................1682
TRIGger<m>:HBTO:ERRor:CRC...................................................................................1683
TRIGger<m>:HBTO:ERRor:SFD....................................................................................1683
TRIGger<m>:HBTO:TYPE <Type>
Selects the type of frame to be triggered on.
Suffix:
<m>
.
1..3
Parameters:
<Type> STARt | MAC | IDLE | ERRor
Protocols