Remote control commands
R&S
®
RTE
1314User Manual 1326.1032.02 ─ 20
Suffix:
<m>
.
Valid suffix numbers: 2 to 21, 61 to 68, 108 to 111, 115 to 118
Source waveform of the measurement, see Chapter 18.4.1,
"Waveform suffix", on page 1072.
Parameters:
<Value> Percentage of the high signal level.
Example:
REFLevel8:RELative:LOWer 15
Sets the lower reference level for Ch3 to 15 %. Ch3 corresponds
to suffix number 8.
Example: See: "Manual reference level definition using relative values"
on page 1057
Usage: Asynchronous command
18.12.13.4 Results
MEASurement<m>:REFLevel:RESult:LOWer?................................................................1314
MEASurement<m>:REFLevel:RESult:MIDDle?............................................................... 1314
MEASurement<m>:REFLevel:RESult:UPPer?................................................................ 1314
MEASurement<m>:REFLevel:RESult:SIGLow?.............................................................. 1314
MEASurement<m>:REFLevel:RESult:SIGHigh?..............................................................1314
MEASurement<m>:REFLevel:RESult:LOWer?
MEASurement<m>:REFLevel:RESult:MIDDle?
MEASurement<m>:REFLevel:RESult:UPPer?
Return the lower, middle, and upper reference level, respectively.
Suffix:
<m>
.
1..10
See "Selection of the measurement: MEASurement<m>"
on page 1249.
Return values:
<Upper> Range: -100E+24 to 100E+24
*RST: 0
Usage: Query only
Asynchronous command
MEASurement<m>:REFLevel:RESult:SIGLow?
MEASurement<m>:REFLevel:RESult:SIGHigh?
Return the signal value that represents a low or high level, respectively.
Suffix:
<m>
.
1..10
See "Selection of the measurement: MEASurement<m>"
on page 1249.