Remote control commands
R&S
®
RTE
1101User Manual 1326.1032.02 ─ 20
Usage: Asynchronous command
DISPlay:SIGBar:HIDE:TRANsparency <HidingTransp>
Sets the transparency of the signal bar when the signal bar is faded out with
DISPlay:SIGBar:HIDE[:AUTO].
Parameters:
<HidingTransp> Range: 20 to 70
Increment: 5
Default unit: %
Usage: Asynchronous command
DISPlay:SIGBar:COLor:BORDer <BorderColor>
Defines the color of the signal bar border.
See also: "To change the colors" on page 117.
Parameters:
<BorderColor> ARGB color value
Range: 0 to 4294967295
Increment: 1
Usage: Asynchronous command
DISPlay:SIGBar:COLor:FILL <FillColor>
Define the fill color of the signal bar.
See also: "To change the colors" on page 117.
Parameters:
<FillColor> ARGB color value
Range: 0 to 4294967295
Increment: 1
Usage: Asynchronous command
18.7.2.5 Waveform labels
To create a waveform label, use DISPlay:SIGNal:LABel:ADD. Using the other
DISP:SIGN:LAB:... commands, you can query the text and position of a label, and
modify the initial settings. The <LabelID> and <Source> parameters identify each label
uniquely. Note that it is not possible to query the <LabelID>, or to read it on the user
interface.
DISPlay:SIGNal:LABel:ADD.......................................................................................... 1102
DISPlay:SIGNal:LABel:REMove.....................................................................................1103
DISPlay:SIGNal:LABel:TEXT.........................................................................................1103
DISPlay:SIGNal:LABel:POSMode.................................................................................. 1104
Instrument setup