Remote control commands
R&S
®
RTE
1920User Manual 1326.1032.02 ─ 20
Parameters:
<Width> Range: 100E-12 to 10000
Increment: 100E-9
*RST: 5E-9
Default unit: s
Usage: Asynchronous command
TRIGger<m>:PARallel:PATTern:WIDTh:DELTa <WidthDelta>
Defines a range around the width value set with TRIGger<m>:PARallel:PATTern:
WIDTh[:WIDTh].
Parameters:
<WidthDelta> Range: 0 to 432
Increment: 500E-12
*RST: 0
Default unit: s
Usage: Asynchronous command
18.18.4.8 Serial pattern trigger
See also:
●
TRIGger<m>:PARallel:SPATtern:CSOurce[:VALue] on page 1913
●
TRIGger<m>:PARallel:SPATtern:EXPRession[:DEFine] on page 1913
TRIGger<m>:PARallel:SPATtern:CSOurce:EDGE <ClockEdge>
Sets the edge of the clock signal. The bit value is determined at the crossing of the
clock edge and the logical threshold.
Parameters:
<ClockEdge> POSitive | NEGative | EITHer
*RST: POSitive
Usage: Asynchronous command
TRIGger<m>:PARallel:SPATtern:PATTern <Pattern>
Defines the serial bit string on which to trigger.
Parameters:
<Pattern> Numeric or string pattern, see Chapter 18.4.6, "Bit pattern
parameter", on page 1076. The bit value X (don't care) is not
allowed.
Usage: Asynchronous command
Mixed signal option (MSO, R&S RTE-B1)