EasyManua.ls Logo

Rohde & Schwarz RTE - Pattern Generator Settings

Rohde & Schwarz RTE
2078 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Waveform generator (Option R&S RTE-B6)
R&S
®
RTE
946User Manual 1326.1032.02 ─ 20
Content and format of the R&S pattern generator *.bin files
For the content of the fields, refer to "Content and format of the R&S*.csv files"
on page 945.
The file stream should contain the following information in the given order:
Bit rate
[double]
High level
[double]
Mask
[string of 8 characters made up of "X"/"1"/"0"]
Number of samples
[UINT32]
Data samples
[UINT8] * number of samples
15.2.2 Pattern generator settings
Enable
Enables the waveform generator/ pattern generator and outputs the signal to the con-
nectors.
Remote command:
WGENerator<m>[:ENABle] on page 1923
PGENerator:ENABle on page 1936
Run mode
Selects the duration for which the signal of the generator will be output after the trigger
event. You can choose between a "Continuous" and "Single period" duration.
Remote command:
PGENerator:RUNMode on page 1937
Bit rate
Sets the number of transmitted bits per second for the pattern generator.
Remote command:
PGENerator:BITRate on page 1936
High level
Sets the high level of the signal.
Remote command:
PGENerator:HLEVel on page 1937
Load pattern file
Opens a dialog for selecting an existing pattern file. It is possible to load .bin or .csv
files, see Chapter 15.2.1, "Content and format of the pattern generator files",
on page 945.
Remote command:
PGENerator:FILE:OPEN on page 1936
PGENerator:FILE[:NAME] on page 1936
Setup of the pattern generator

Table of Contents

Other manuals for Rohde & Schwarz RTE