Remote control commands
R&S
®
RTE
1097User Manual 1326.1032.02 ─ 20
Setting parameters:
<Source> See LAYout:SIGNal:ASSign on page 1096 and Chap-
ter 18.4.2, "Waveform parameter", on page 1074
Example: See Chapter 18.3.1.1, "Creating diagrams (SmartGrid)",
on page 1055.
Usage: Setting only
Asynchronous command
18.7.2.4 Diagram layout
The following commands belong to the settings in "Display" > "Diagram Layout". To
configure the SmartGrid, use the commands described in Chapter 18.7.2.3, "Smart-
grid", on page 1094.
These settings are user-specific, they are not reset by [PRESET] and *RST. You can
reset them to default values using [FILE] > "Save/Recall > User defined preset > Fac-
tory defaults" or using the SYSTem:PRESet command.
DISPlay:DIAGram:REName.......................................................................................... 1097
DISPlay:DIAGram:GRID............................................................................................... 1098
DISPlay:DIAGram:CROSshair.......................................................................................1098
DISPlay:DIAGram:FINegrid...........................................................................................1098
DISPlay:DIAGram:LABels.............................................................................................1098
DISPlay:DIAGram:TITLe...............................................................................................1098
DISPlay:DIAGram:YFIXed............................................................................................ 1099
DISPlay:DIAGram:XFIXed............................................................................................ 1099
DISPlay:GATE:TRANsparency...................................................................................... 1099
DISPlay:RESultboxes:DEFaultpos................................................................................. 1099
DISPlay:SIGBar[:STATe]............................................................................................... 1100
DISPlay:SIGBar:POSition..............................................................................................1100
DISPlay:SIGBar:HIDE[:AUTO].......................................................................................1100
DISPlay:SIGBar:HIDE:TIME..........................................................................................1100
DISPlay:SIGBar:HIDE:HEAD.........................................................................................1100
DISPlay:SIGBar:HIDE:TRANsparency............................................................................1101
DISPlay:SIGBar:COLor:BORDer....................................................................................1101
DISPlay:SIGBar:COLor:FILL......................................................................................... 1101
DISPlay:DIAGram:REName <DiagramName>, <NewName>
Changes the diagram name, which is displayed on the diagram tab.
Setting parameters:
<DiagramName> String with the existing diagram name.
<NewName> String with the new diagram name.
Example:
:DISPlay:DIAGram:REName "Diagram1",'Test A'
Usage: Setting only
Instrument setup

Table of Contents

Other manuals for Rohde & Schwarz RTE