Remote control commands
R&S
®
RTE
1096User Manual 1326.1032.02 ─ 20
Usage: Setting only
Asynchronous command
LAYout:SHOW <DiagramName>
Selects the specified diagram.
Setting parameters:
<DiagramName> String with the name of the diagram
Example: See Chapter 18.3.1.1, "Creating diagrams (SmartGrid)",
on page 1055.
Usage: Setting only
Asynchronous command
LAYout:SIGNal:ASSign
<DiagramName>, <Source>
Shows the specified waveform in the selected diagram.
Setting parameters:
<DiagramName> String with the diagram name
<Source> C1W1 | C2W1 | C3W1 | C4W1 | M1 | M2 | M3 | M4 | M5 | M6 |
M7 | M8 | R1 | R2 | R3 | R4 | XY1 | XY2 | XY3 | XY4 |
MRESult1 | MRESult2 | MRESult3 | MRESult4 | MRESult5 |
MRESult6 | MRESult7 | MRESult8 | SBUS1 | SBUS2 | SBUS3 |
SBUS4 | D0 | D1 | D2 | D3 | D4 | D5 | D6 | D7 | D8 | D9 | D10 |
D11 | D12 | D13 | D14 | D15 | MSOB1 | MSOB2 | MSOB3 |
MSOB4 | TRK1 | TRK2 | TRK3 | TRK4 | TRK5 | TRK6 | TRK7 |
TRK8 | Z1V1 | Z1V2 | Z1V3 | Z1V4 | Z1I1 | Z1I2 | Z1I3 | Z1I4 |
Z2V1 | Z2V2 | Z2V3 | Z2V4 | Z2I1 | Z2I2 | Z2I3 | Z2I4 | DIFF1 |
DIFF2 | COMMON1 | COMMON2
Waveform to be assigned, see Chapter 18.4.2, "Waveform
parameter", on page 1074
Spectrum Analysis, option R&S RTE-K18: Spectrograms and
timeline spectrums are automatically displayed in their own dia-
grams.
Example:
See Chapter 18.3.1.1, "Creating diagrams (SmartGrid)",
on page 1055.
Usage: Setting only
Asynchronous command
LAYout:SIGNal:UNASsign <Source>
Minimizes the specified waveform, i.e. removes it from the diagram and shows it in the
signal icon.