Remote control commands
R&S
®
RTE
1289User Manual 1326.1032.02 ─ 20
18.12.8 Statistics and long-term measurements
See also: Chapter 18.16.9, "Long term measurement results and measurement histo-
gram export to file", on page 1410.
MEASurement<m>:STATistics[:ENABle].........................................................................1289
MEASurement<m>:CLEar.............................................................................................1289
MEASurement<m>:MULTiple........................................................................................ 1290
MEASurement<m>:MNOMeas...................................................................................... 1290
MEASurement<m>:STATistics:HISTogram......................................................................1290
MEASurement<m>:STATistics:HBINs.............................................................................1291
MEASurement<m>:STATistics:MODE............................................................................ 1291
MEASurement<m>:STATistics:RCOunt.......................................................................... 1291
MEASurement<m>:STATistics:RMEascount................................................................... 1292
MEASurement<m>:STATistics:RTIMe............................................................................ 1292
MEASurement<m>:STATistics:RESet.............................................................................1292
MEASurement<m>:VERTical:CONT.............................................................................. 1293
MEASurement<m>:VERTical:AUTO...............................................................................1293
MEASurement<m>:VERTical:OFFSet............................................................................ 1293
MEASurement<m>:VERTical:SCALe............................................................................. 1294
MEASurement<m>:LTMeas[:STATe].............................................................................. 1294
MEASurement<m>:LTMeas:COUNt...............................................................................1294
MEASurement<m>:LTMeas:TIME..................................................................................1295
MEASurement<m>:STATistics[:ENABle] <StatisticsState>
Enables statistics calculation for the measurement.
For details on the statistics results, see Chapter 8.2.10.1, "Statistics", on page 382.
Suffix:
<m>
.
The suffix is irrelevant, the command enables statistics for all
measurements.
Parameters:
<StatisticsState> ON | OFF
*RST: OFF
Usage: Asynchronous command
MEASurement<m>:CLEar
Deletes the statistic results of the indicated mesurement.
Suffix:
<m>
.
1..10
See "Selection of the measurement: MEASurement<m>"
on page 1249.
Usage: Event
Asynchronous command