Protocol analysis
R&S
®
RTE
658User Manual 1326.1032.02 ─ 20
10. Tap "Result Analysis".
11. Set the "Vertical scaling" to "Continuous auto scale".
12. Start continuous acquisition.
The trend fills up with measurement points from left to right.
13. If you want to change the vertical scaling of the trend curve, disable "Continuous
auto scale" and adjust "Vertical scale" and "Vertical offset".
13.9 MIL-1553 (option R&S RTE-K6)
13.9.1 The MIL-STD-1553
The MIL-STD-1553 specification defines the characteristics of a serial data bus origi-
nally designed for use in the military avionics. Nowadays it is also used in spacecraft
on-board data handling.
The bus is a 2-wire bus that uses differential signals.
A MIL-STD-1553 system consists of the following components:
Bus Controller (BC): initiates and coordinates the data flow in the system.
Remote Terminal (RT): interfaces various subsystems with the data bus. A system
consists of up to 31 RTs and each RT can have 31 subaddresses.
The subaddresses 0 and 31 refer to a mode code command.
Bus Monitor (BM) (optional): listens to all messages and can record selected data
for real-time or off-line analysis.
The information is transmitted over the bus in defined series of words using Manches-
ter code, where each bit is transmitted as high-low for a logical 1 or a low-high for a
logical 0. There are three types of words: command, data and status.
MIL-1553 (option R&S
RTE-K6)