Mixed signal option (MSO, R&S RTE-B1)
R&S
®
RTE
910User Manual 1326.1032.02 ─ 20
For details, see: Chapter 14.3.1, "Trigger settings for digital signals and parallel buses",
on page 910.
Also, you can define trigger holdoff conditions. See Chapter 6.4, "Holdoff",
on page 264.
14.3.1 Trigger settings for digital signals and parallel buses
Depending on the selected source, the instrument provides the appropriate trigger
types and the corresponding trigger settings.
The settings in the "Setup" tab are:
Basic trigger settings.............................................................................................910
Edge......................................................................................................................911
Width.....................................................................................................................912
Timeout................................................................................................................. 913
Data2Clock............................................................................................................914
State......................................................................................................................915
Pattern...................................................................................................................916
Serial pattern.........................................................................................................919
14.3.1.1 Basic trigger settings
The basic trigger settings for MSO are the trigger source and the trigger type. They are
selected in the upper part of the "Trigger" dialog box.
Make sure that the trigger sequence is set to "A only".
Also, you can define trigger holdoff conditions. See Chapter 6.4, "Holdoff",
on page 264.
Source
If the Mixed Signal Option is installed, the variety of trigger sources is enhanced with
specific digital trigger sources. As a trigger source you can select:
One of the digital channels "D0" ... "D15"
D2
D0 D1
A logic combination of digital channels: "Logic"
One of the parallel buses "Par. bus1" ... "Par. bus4"
PB
3
PB
2
PB
1
Remote command:
TRIGger<m>:SOURce[:SELect] on page 1165