Remote control commands
R&S
®
RTE
1343User Manual 1326.1032.02 ─ 20
MTESt:WFMRescale:YPOSition <MaskTestName>,<VertPosi>
MTESt:WFMRescale:YPOSition? <MaskTestName>
Moves the mask vertically within the display.
Parameters:
<VertPosi> Range: -1000 to 1000
Increment: 0.01
*RST: 0
Default unit: div
Parameters for setting and query:
<MaskTestName> String containing the name of the mask test
Usage: Asynchronous command
MTESt:WFMRescale:YSTRetch
<MaskTestName>,<VerticalStretch>
MTESt:WFMRescale:YSTRetch? <MaskTestName>
Sets the vertical scaling to stretch the mask in y-direction. The scaling axis is the hori-
zontal line through the lowest value of the lower mask limit.
Parameters:
<VerticalStretch> Scale factor in %
Range: 10 to 1000
Increment: 1
*RST: 100
Default unit: %
Parameters for setting and query:
<MaskTestName> String containing the name of the mask test
Usage: Asynchronous command
18.14.4 Event actions
MTESt:ONViolation:BEEP.............................................................................................1343
MTESt:ONViolation:STOP.............................................................................................1344
MTESt:ONViolation:PRINt.............................................................................................1344
MTESt:ONViolation:SAVewaveform............................................................................... 1344
MTESt:ONViolation:REPort...........................................................................................1345
MTESt:ONViolation:TRIGgerout.................................................................................... 1345
MTESt:ONViolation:RUNexec....................................................................................... 1345
MTESt:ONViolation:BEEP <MaskTestName>,<Beep>
MTESt:ONViolation:BEEP? <MaskTestName>
Generates a beep sound for the specified event.
Mask testing