Protocol analysis
R&S
®
RTE
596User Manual 1326.1032.02 ─ 20
Figure 13-28: Result table and decoded CAN signal with applied DBC file and zoom on EngineData
message
Remote command:
BUS<m>:CAN:FRAMe<n>:SDATa? on page 1526
BUS<m>:CAN:FRAMe<n>:SDEXport? on page 1508
13.5.7.3 Symbolic search
Access: [SEARCH] > "Setup" tab > "Symbolic" = on
If a DBC file is applied, the symbolic search for messages and signal, which are
defined in the DBC file, is available. Symbolic search is an alternative to the other
search criteria, you can either search for symbolic values or for an AND-combination of
the other 5 criteria.