Remote control commands
R&S
®
RTE
1366User Manual 1326.1032.02 ─ 20
SHORter
Triggers on pulses shorter than the given "Width".
LONGer
Triggers on pulses longer than the given "Width".
*RST: WITHin
Parameters for setting and query:
<SearchName> Search definition
Example: See Chapter 18.3.4.1, "Searching for a pulse of specified width",
on page 1060
Usage: Asynchronous command
SEARch:TRIGger:WIDTh:WIDTh <SearchName>,<Width>
SEARch:TRIGger:WIDTh:WIDTh? <SearchName>
For the ranges "Within" and "Outside", the width defines the center of a range which is
defined by the limits "±Delta".
For the ranges "Shorter" and "Longer", the width defines the maximum and minimum
pulse width, respectively.
The range is defined using SEARch:TRIGger:WIDTh:RANGe.
Parameters:
<Width> Range: 100E-12 to 864
Increment: 100E-9
*RST: 5E-9
Default unit: s
Parameters for setting and query:
<SearchName> Search definition
Example: See Chapter 18.3.4.1, "Searching for a pulse of specified width",
on page 1060
Usage: Asynchronous command
18.15.10 Window search conditions
SEARch:TRIGger:WINDow:DELTa.................................................................................1367
SEARch:TRIGger:WINDow:RANGe...............................................................................1367
SEARch:TRIGger:WINDow:TIMerange.......................................................................... 1368
SEARch:TRIGger:WINDow:WIDTh................................................................................1368
SEARch:TRIGger:LEVel:WINDow:LOWer.......................................................................1369
SEARch:TRIGger:LEVel:WINDow:UPPer....................................................................... 1369
Search