Power analysis (option R&S RTE-K31)
R&S
®
RTE
986User Manual 1326.1032.02 ─ 20
6. Select the correct channels for the "Current Source" and the "Voltage Source".
7. Select the "Settings" tab.
8. If "Average" is selected, enter the "Average count", that is the number of wave-
forms used for average calculation.
9. Set the reset condition for the average calculation:
● If "Time" is selected, enter the "Reset time".
● If "Waveforms" is selected, enter the "Reset count".
10. Select an "Optimize Scaling" option.
11. Tap "Execute".
12. If needed adjust the cursors manually.
You can tap on a cursor and change its position with the [NAVIGATION] rotary
knob.
On the screen, you can see the measurement waveforms of the current and the
voltage. Also, the result box displays the dynamic on resistance. For details, see
Chapter 16.4.2.1, "Dynamic on resistance results", on page 984.
16.4.2.3 Dynamic on resistance settings
In the "Channels" tab, you set the current source and the voltage source, see also:
Chapter 16.2.1, "Channels tab", on page 965.
In the "Settings" tab, you configure the power measurement parameters and display
settings.
Control loop