Protocol analysis
R&S
®
RTE
715User Manual 1326.1032.02 ─ 20
For common display settings, see Chapter 13.1.3, "Display", on page 515.
To enhance the decode possibilities of the 100BASE-T1 protocol, you can use an addi-
tional setting in the "Display" tab: "Decode layer".
Decode layer
Selects the decode layer.
Decoding is performed in several steps, and the end results are presented in the
decode table. The decode layer selects an interim step for which the decoding result is
shown in the honeycomb display.
"Off"
No decode layer is displayed.
"Ternary sym-
bols"
Decoded ternary symbols.
"Scrambled
bits"
Scrambled ternary bits.
"Descrambled
bits"
Descrambled ternary bits.
"Reversed
Bits"
Reserved bits
13.12.2.3 Configuring 100BASE-T1 signals
For configuration, assign the lines to the input channels and define the active states
and the logical thresholds.
For details on configuration settings, see Chapter 13.12.2.1, "100BASE-T1 configura-
tion settings", on page 712.
Serial bus setup
1. Press the [PROTOCOL] key on the front panel.
Ethernet 100BASE-T1 (option R&S
RTE-57)