Remote control commands
R&S
®
RTE
1748User Manual 1326.1032.02 ─ 20
18.17.15.2 Trigger
The trigger suffix <m> is always 1 and can be omitted. It selects the trigger event: Only
the A-trigger is available for triggering on serial buses.
To trigger on a serial bus, make sure that:
TRIGger<m>:SOURce[:SELect] is set to SBUS.
The sources of the serial bus are channel signals: use BUS<m>:...:SOURce
commands.
Decoding is enabled: BUS<m>[:STATe] is set to ON.
TRIGger<m>:CMSB:TYPE............................................................................................1748
TRIGger<m>:CMSB:PATTern........................................................................................ 1749
TRIGger<m>:CMSB:ICONdition.................................................................................... 1749
TRIGger<m>:CMSB:IMIN............................................................................................. 1749
TRIGger<m>:CMSB:IMAX............................................................................................ 1750
TRIGger<m>:CMSB:NRZ:WRDLength...........................................................................1750
TRIGger<m>:CMSB:ADVanced:FRAMe<n>:ENABle....................................................... 1750
TRIGger<m>:CMSB:ADVanced:FRENable..................................................................... 1750
TRIGger<m>:CMSB:ADVanced:FRAMe<n>:FLD<o>:ENABle...........................................1750
TRIGger<m>:CMSB:ADVanced:FIENable.......................................................................1750
TRIGger<m>:CMSB:ADVanced:FRAMe<n>:FLD<o>:BIT.................................................1751
TRIGger<m>:CMSB:ADVanced:BIT...............................................................................1751
TRIGger<m>:CMSB:ADVanced:FRAMe<n>:FLD<o>:DMAX.............................................1751
TRIGger<m>:CMSB:ADVanced:DMAX...........................................................................1751
TRIGger<m>:CMSB:ADVanced:FRAMe<n>:FLD<o>:DMIN..............................................1752
TRIGger<m>:CMSB:ADVanced:DMIN............................................................................1752
TRIGger<m>:CMSB:ADVanced:FRAMe<n>:FLD<o>:DOPerator...................................... 1752
TRIGger<m>:CMSB:ADVanced:DOPerator.....................................................................1752
TRIGger<m>:CMSB:ADVanced:ERRor<n>:ENABle........................................................ 1752
TRIGger<m>:CMSB:ADVanced:ERENable.....................................................................1752
TRIGger<m>:CMSB:ADVanced:FRAMe<n>:FLD<o>:IMAX..............................................1753
TRIGger<m>:CMSB:ADVanced:IMAX............................................................................ 1753
TRIGger<m>:CMSB:ADVanced:FRAMe<n>:FLD<o>:IMIN............................................... 1753
TRIGger<m>:CMSB:ADVanced:IMIN............................................................................. 1753
TRIGger<m>:CMSB:ADVanced:FRAMe<n>:FLD<o>:IOPerator........................................1753
TRIGger<m>:CMSB:ADVanced:IOPerator......................................................................1753
TRIGger<m>:CMSB:TYPE <Type>
Selects the trigger type for custom serial bus analysis.
Suffix:
<m>
.
1..3
Parameters:
<Type> STARt | PATTern | ADVanced
STARt
Triggers on the frame start, which is the end of the gap time as
specified in BUS<m>:CMSB:GAPTime:VALue on page 1742
Protocols