Remote control commands
R&S
®
RTE
1955User Manual 1326.1032.02 ─ 20
POWer:INRush:REPort:ADD
Adds the result to the report list.
Usage: Event
18.20.6 Current harmonic
POWer:HARMonics:AUTO............................................................................................1955
POWer:HARMonics:DOFR............................................................................................1955
POWer:HARMonics:ENFR............................................................................................1955
POWer:HARMonics:MIFR.............................................................................................1956
POWer:HARMonics:EVAL.............................................................................................1956
POWer:HARMonics:EXECute....................................................................................... 1956
POWer:HARMonics:REPort:ADD...................................................................................1956
POWer:HARMonics:RESult<m>:STDinuse?................................................................... 1956
POWer:HARMonics:RESult<m>:FREQuency<n>:VALue?................................................1956
POWer:HARMonics:RESult<m>:MAXValue<n>:VALue?.................................................. 1956
POWer:HARMonics:RESult<m>:STDValue<n>:VALue?...................................................1956
POWer:HARMonics:RESult<m>:VALue<n>:VALue?........................................................1956
POWer:HARMonics:STAN............................................................................................ 1957
POWer:HARMonics:VOLT.............................................................................................1957
POWer:HARMonics:AUTO <Autoscale>
Selects the scaling for the display of the results.
Parameters:
<Autoscale> AUTO | MANUAL
*RST: MANUAL
POWer:HARMonics:DOFR <FrequencyDOA160>
Selects the frequency of the input signal.
Parameters:
<FrequencyDOA160> F360 | F400 | F650 | F800
*RST: F400
POWer:HARMonics:ENFR <FreqEN61000>
Selects the frequency of the input signal.
Parameters:
<FreqEN61000> F50 | F60
*RST: F50