1911User Manual 1326.1032.02 ─ 20
ACQuire:POINts:DVALue?
Returns the current digital record length used by each digital channel.
Return values:
<DigReclgth> Range: 1000 to 200E6
Increment: 2
*RST: 1000
Default unit: pts
Usage: Query only
Asynchronous command
18.18.4 Trigger settings for digital signals and parallel buses
In all TRIGger<m>:PARallel commands, the trigger suffix <m> is always 1 and can
be omitted. It selects the trigger event: Only the A-trigger is available for triggering on
digital signals and parallel buses.
General commands.............................................................................................1911
Edge trigger.........................................................................................................1913
Width trigger........................................................................................................1914
Timeout trigger.................................................................................................... 1915
Data2Clock trigger.............................................................................................. 1916
State trigger.........................................................................................................1917
Pattern trigger..................................................................................................... 1918
Serial pattern trigger............................................................................................1920
18.18.4.1 General commands
TRIGger<m>:SOURce[:SELect].....................................................................................1911
TRIGger<m>:PARallel:TYPE.........................................................................................1913
TRIGger<m>:PARallel:DATatoclock:CSOurce[:VALue]..................................................... 1913
TRIGger<m>:PARallel:STATe:CSOurce:VALue................................................................1913
TRIGger<m>:PARallel:SPATtern:CSOurce[:VALue]......................................................... 1913
TRIGger<m>:PARallel:EDGE:EXPRession[:DEFine]........................................................1913
TRIGger<m>:PARallel:WIDTh:EXPRession[:DEFine].......................................................1913
TRIGger<m>:PARallel:TIMeout:EXPRession[:DEFine].....................................................1913
TRIGger<m>:PARallel:STATe:EXPRession[:DEFine]........................................................1913
TRIGger<m>:PARallel:PATTern:EXPRession[:DEFine].....................................................1913
TRIGger<m>:PARallel:SPATtern:EXPRession[:DEFine]................................................... 1913
TRIGger<m>:SOURce[:SELect] <SourceDetailed>
Selects the source of the trigger signal.
Mixed signal option (MSO, R&S