Remote control commands
R&S
®
RTE
1960User Manual 1326.1032.02 ─ 20
POWer:DONRes:EXECute
Starts the dynamic on resistance measurement.
Usage: Event
Asynchronous command
POWer:DONRes:GATE<m>:STARt <Start>
POWer:DONRes:GATE<m>:STOP <Stop>
Sets the value for the cursor.
Suffix:
<m>
.
1..2
Parameters:
<Stop>
POWer:DONRes:REPort:ADD
Adds the result to the report list.
Usage:
Event
POWer:DONRes:RESult:RESistance?
Returns the the dynamic on resistance value.
Return values:
<Resistance> Range: -100E+24 to 100E+24
*RST: 0
Default unit: \x2126
Usage: Query only
18.20.9 Slew rate
POWer:SLEWrate:SOURce.......................................................................................... 1961
POWer:SLEWrate:AUTO.............................................................................................. 1961
POWer:SLEWrate:AVGDeriv.........................................................................................1961
POWer:SLEWrate:EXECute..........................................................................................1961
ACQuire:ARESet:MODE...............................................................................................1961
ACQuire:ARESet:TIME.................................................................................................1962
ACQuire:ARESet:COUNt.............................................................................................. 1962
POWer:SLEWrate:GATE:STARt.................................................................................... 1962
POWer:SLEWrate:GATE:STOP.....................................................................................1962
POWer:SLEWrate:REPort:ADD..................................................................................... 1962
POWer:SLEWrate:RESult:ACTual?................................................................................1962
POWer:SLEWrate:RESult:AVG?....................................................................................1962
POWer:SLEWrate:RESult:EVTCount?........................................................................... 1962
POWer:SLEWrate:RESult:NPEak?................................................................................ 1962
Power analysis (option R&S