EasyManua.ls Logo

Rohde & Schwarz RTE - Edge Trigger

Rohde & Schwarz RTE
2078 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote control commands
R&S
®
RTE
1913User Manual 1326.1032.02 ─ 20
TRIGger<m>:PARallel:TYPE <Type>
Selects the trigger type to trigger on digital channels and parallel buses.
To trigger on analog channels or the external trigger input, use TRIGger<m>:TYPE.
Parameters:
<Type> EDGE | WIDTh | TIMeout | DATatoclock | STATe | PATTern |
SERPattern |
SERPattern = serial pattern trigger
*RST: EDGE
Usage: Asynchronous command
TRIGger<m>:PARallel:DATatoclock:CSOurce[:VALue] <ClockSource>
TRIGger<m>:PARallel:STATe:CSOurce:VALue <ClockSource>
TRIGger<m>:PARallel:SPATtern:CSOurce[:VALue] <ClockSource>
Selects the digital channel of the clock signal.
Parameters:
<ClockSource> D0 | D1 | D2 | D3 | D4 | D5 | D6 | D7 | D8 | D9 | D10 | D11 | D12 |
D13 | D14 | D15
*RST: D0
Usage: Asynchronous command
TRIGger<m>:PARallel:EDGE:EXPRession[:DEFine] <LogicalExpr>
TRIGger<m>:PARallel:WIDTh:EXPRession[:DEFine] <LogicalExpr>
TRIGger<m>:PARallel:TIMeout:EXPRession[:DEFine] <LogicalExpr>
TRIGger<m>:PARallel:STATe:EXPRession[:DEFine] <LogicalExpr>
TRIGger<m>:PARallel:PATTern:EXPRession[:DEFine] <LogicalExpr>
TRIGger<m>:PARallel:SPATtern:EXPRession[:DEFine] <LogicalExpr>
Defines a logical combination of several digital channels as trigger condition if
TRIGger<m>:SOURce[:SELect] is set to LOGIC.
Parameters:
<LogicalExpr> String with logical expression
Example:
TRIGger:PARallel:EDGE:EXPRession 'D1 and D2'
Usage: Asynchronous command
18.18.4.2 Edge trigger
See also:
TRIGger<m>:PARallel:EDGE:EXPRession[:DEFine] on page 1913
TRIGger<m>:PARallel:EDGE:SLOPe.............................................................................1914
Mixed signal option (MSO, R&S
RTE-B1)

Table of Contents