EasyManua.ls Logo

Rohde & Schwarz RTE - Trigger

Rohde & Schwarz RTE
2078 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote control commands
R&S
®
RTE
1778User Manual 1326.1032.02 ─ 20
BUS<m>:MDIO:DATA:THReshold:LOW <ThresDatLow>
Defines the lower threshold level for the data signal.
Suffix:
<m>
.
1..4
Parameters:
<ThresDatLow> Range: -5 to 5
Increment: 0.1
*RST: 0.8
Default unit: V
BUS<m>:MDIO:PRESet
<Preset>
Selects the default threshold settings according to the Ethernet standard: 2.0 V and
0.8 V.
Suffix:
<m>
.
1..4
Parameters:
<Preset> DEFault | MANual
*RST: DEFault
BUS<m>:MDIO:COUPling <ThresCpl>
Overwrites the data thresholds with the clock thresholds.
Suffix:
<m>
.
1..4
Parameters:
<ThresCpl> ON | OFF
*RST: ON
18.17.16.2 Trigger
The trigger suffix <m> is always 1 and can be omitted. It selects the trigger event: Only
the A-trigger is available for triggering on serial buses.
To trigger on a serial bus, make sure that:
TRIGger<m>:SOURce[:SELect] is set to SBUS.
The sources of the serial bus are channel signals: use BUS<m>:...:SOURce
commands.
Decoding is enabled: BUS<m>[:STATe] is set to ON.
TRIGger<m>:MDIO:TYPE.............................................................................................1779
TRIGger<m>:MDIO:ST.................................................................................................1779
TRIGger<m>:MDIO:FRAMetype....................................................................................1780
Protocols

Table of Contents

Other manuals for Rohde & Schwarz RTE